Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Sign In to gain access to subscriptions and/or personal tools.
Transactions of the Institute of Measurement and Control
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Jones, A.
Right arrow Articles by Kell, D.B.
Right arrow Search for Related Content
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

An instrument for the acquisition and analysis of the nonlinear dielectric spectra of biological samples

A. Jones, BSc, PhD

Dept. of Computer Science, University of Wales, Aberystwyth. UK

J.J. Rowland, MSc, CEng, MIEE

Dept. of Computer Science, University of Wales, Aberystwyth. UK

A.M. Woodward, BSc, PhD

Institute of Biological Sciences, University of Wales, Aberystwyth, UK

D.B. Kell, MA, DPhil

Institute of Biological Sciences, University of Wales, Aberystwyth, UK

Nonlinear dielectric spectroscopy is, potentially, a powerful non-invasive method of monitoring biological cell activity, with possible applications in biotechnology and in medicine. This paper describes the design and implementation of an integrated instrument for obtaining and analysing the nonlinear dielectric spectra of biological cell suspensions. The instrument is based on an IBMcompatible personal computer equiped with an AT&T digital signal processor and 16-bit analogue I/O. It allows collection of resultant power spectra in real time during optimal time sweeps over a wide range of excitation voltages and frequencies. Further analysis of the sets of spectra is undertaken by means of mutivariate calibration. Examples are included of results obtained and it concludes with a brief discussion of the present limitations of the method.

Key Words: Nonlinear dielectrics • instrumentation • multivariate calibration • fermentation.

Transactions of the Institute of Measurement and Control, Vol. 19, No. 5, 223-230 (1997)
DOI: 10.1177/014233129701900502