Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Sign In to gain access to subscriptions and/or personal tools.
Transactions of the Institute of Measurement and Control
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Werner, J.
Right arrow Articles by Kloppe, A.
Right arrow Search for Related Content
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

Sensor and control technology for cardiac pacing

Jürgen Werner

Ruhr-University, Faculty of Medicine, Department of Biomedical Engineering, MA 4/59, 44780 Bochum, Germany, wernerKbiomed.ruhruni-bochum.de

Mathias Meine

Ruhr-University, Faculty of Medicine, Department of Biomedical Engineering, MA 4/59, 44780 Bochum, Germany

Karsten Hoeland

Ruhr-University, Faculty of Medicine, Department of Biomedical Engineering, MA 4/59, 44780 Bochum, Germany

Martin Hexamer

Ruhr-University, Faculty of Medicine, Department of Biomedical Engineering, MA 4/59, 44780 Bochum, Germany

Axel Kloppe

Ruhr-University, Faculty of Medicine, Department of Biomedical Engineering, MA 4/59, 44780 Bochum, Germany

Pacemakers are implanted on account of deficiencies in rhythm generation and excitation conduction in the heart. The aim of sensor-controlled pacemaker systems is, apart from the preservation of life, the greatest possible restoration of physiological adaptation to circulatory stress. If the intrinsic rhythm generator breaks down, this cannot be achieved ideally by a technical shunt, but approximately by sensing physical and/or physiological variables suited to heart rate control. The latter leads both to feedforward control systems and to feedback (closed) control loops. After an overview on existing sensors the authors offer two new sensor technologies for closed-loop systems which are optimally suited to restore the original physiological control loop to the utmost extent. One uses sensors measuring the atrio-ventricular delay in the heart (dromotropic pacemaker), and the other uses a fibre optic sensor measuring the contraction of the heart (inotropic pacemaker).

Key Words: closed-loop control • heart pacemaker • sensors

Transactions of the Institute of Measurement and Control, Vol. 22, No. 4, 289-302 (2000)
DOI: 10.1177/014233120002200402


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?