Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Click here to sign up for SAGE Journal Email Alerts today!

Sign In to gain access to subscriptions and/or personal tools.
Transactions of the Institute of Measurement and Control
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Blom, J. A.
Right arrow Articles by Hoeksel, S. A.A.P.
Right arrow Search for Related Content
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

Control aspects of clinical support systems

J. A. Blom

Department of Electrical Engineering, Measurement and Control Group, Eindhoven University of Technology, The Netherlands, j.a.blomKele.tue.nl

S. A.A.P. Hoeksel

Cardiovascular Research Institute, Department of Anaesthesiology, Maastricht University, The Netherlands

Standard control theory approaches alone are not sufficient for the design of clinical control systems. Additional medical expertise has to be incorporated in order to achieve high quality and robust performance. The main problem to be overcome is the fact that no real time identifiability of the patient’s characteristics can be guaranteed, due to the low signal-to-noise ratio of the feedback signals in combination with unknown and possibly rapid changes in patient characteristics. Solutions to this problem are suggested by the manual control methods of expert clinicians. One solution is to adjust the controller’s parameters through monitoring its control performance. Another solution, in multi-input-multi-output controllers, is to allow variation of only one drug at a time. In addition, sometimes other goals are more important than keeping feedback signals at setpoint values. These goals need to be part of the clinical support system as well. The success of adding clinician-derived heuristics to standard control systems is illustrated by a number of single and multiple drug controllers, whose goal it is to support the clinician in the stabilization of the systemic arterial and/or the pulmonary artery pressure during and after cardiac surgery.

Key Words: clinical control systems • drug response • heuristics • induced hypotension • modelling • nitroglycerin • nitroprusside • real time expert systems

Transactions of the Institute of Measurement and Control, Vol. 22, No. 4, 331-352 (2000)
DOI: 10.1177/014233120002200404